14-45 KW Silent Pac Generator Sets

- Modular design allows for open or enclosed unit operation
- Heavy-duty water-cooled YANMAR engine series TNV Compatible with Tier II, Tier III, and Tier IV engines
- 12-lead continuous duty COLISEUM generator Oversized able to operate single or three phase at full - power Insulation class H, vacuum impregnated and tropicalized
- Sound attenuated and weather-proof housing (NEMA 3R)
- Lockable doors and control panel window
- Lockable door on top of enclosure for filling radiator fluid
- Four lifting eyes for lifting complete gen set
- Rugged welded double-walled base fuel tank for 24-hrs operation
- UL listed generator set (pending - expected in 2008)





POWER

MCGS14

MCGS18

MCGS23

MCGS37

MCGS45

1 ø Continuous Duty

12.6 kW

17 kW

21 kW

32 kW

40 kW

1 ø Standby Duty

13.8 kW

18.5 kW

23.5 kW

36.5 kW

45 kW

1 ø Power Factor

1

1

1

1

1

3 ø Continuous Duty

12.6 kW

17 kW

21 kW

32 kW

40 kW

3 ø Standby Duty

13.8 kW

18.5 kW

23.5 kW

36.5 kW

45 kW

3 ø Power Factor

0.8

0.8

0.8

0.8

0.8

GENERATOR HEAD

Model

GB20

GB25

GB30

GB45

GB60

kW 3 phase Rating

20 kW

25 kW

30 kW

45 kW

60 kW

Number of Stator Leads

12

12

12

12

12

Frequency

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

Running Speed ( RPM )

1800

1800

1800

1800

1800

Temperature Rise

105°C

105°C

105°C

105°C

105°C

Ambient Temperature

40°C

40°C

40°C

40°C

40°C

Insulation Class

H 180°C

H 180°C

H 180°C

H 180°C

H 180°C

ENGINE

Model

3TNV88

4TNV88

4TNV84T

4TNV98

4TNV98T

Power Rating ISO 3046(ICN)

14.7 kW

19.6 kW

24.2 kW

36.4 kW

45.6 kW

PRP Prime Power

1800 RPM

1800 RPM

1800 RPM

1800 RPM

1800 RPM

Power Rating ISO 3046(IFN)

16.2 kW

21.6 kW

26.8 kW

40.8 kW

50.6 kW

LTP Limited Time Power

1800 RPM

1800 RPM

1800 RPM

1800 RPM

1800 RPM

Number of Cylinders

3

4

4

4

4

Bore / Stroke ( mm )

88 / 90

88 / 90

84 / 90

98 / 110

98 / 110

Displacement ( cc )

1642

2189

1995

3319

3319

Fuel Consumption per Hour, 100 %

1.0 gal

1.33 gal

1.53 gal

2.30 gal

2.50 gal

( 3.75 l )

( 4.96 l )

( 6.12 l )

( 8.71 l )

( 9.47 l )

Fuel Tank Capacity, Double-Walled

30 gal

39.5 gal

39.5 gal

61 gal

61 gal

( 114 l )

( 150 l )

( 150 l )

( 231 l )

( 231 l )

Starting System,

1.2 kW

1.4 kW

1.4 kW

2.3 kW

2.3 kW

Electrical

12 V

12 V

12 V

12 V

12 V

EPA Approved

YES

YES

YES

YES

YES

ENCLOSURE

Enclosure Protection

NEMA 3R

NEMA 3R

NEMA 3R

NEMA 3R

NEMA 3R

Soundproofing dB at 1 m

≤ 80 dB

≤ 80 dB

≤ 80 dB

≤ 80 dB

≤ 80 dB

Dimensions L x W x H (Inches)

65x31.5x48.6

74.8x31.5x47

74.8x31.5x47

84.6x35.4x49.2

84.6x35.4x49.2

L x W x H (Centimeters)

(165x80x119)

(190x80x119)

(190x80x119)

(215x90x125)

(215x90x125)


 

Subscribe to our live news feed! LATEST NEWS:


Directions to Bell Power and Surrounding Sights

TESTIMONIALS:

 

When we receive the engines, they come fully accessorized, fully enclosed, and painted red - ready to fit into our machines. They always bend over backwards to help us out in a tight bind. They are one of the best companies we do business with. It's been a very,very, good marriage.

 
Butch Rogers
Timber Wolf Corp.
 
Customize your engine spec and request further information from Bell Power!
John Deere Engine Products Yanmar Engine Products Scania Engine Products Funk Drivetrain Components John Deere Remanufactured Select Components Murphy