John Deere Powered Generator Sets - Tier 3
John Deere powered generator sets built for dependable performance in emergency or prime power applications. Economical to run and sized to meet the needs of the private or commercial user.
John Deere quality backed by John Deere warranty and service.
View the generator set pocket guide
Tier III Specifications
STANDARD 60 HERTZ / 1800 RPM RATINGS
Note: The (kVA) Calculated Rating Range is determined by a 0.8 power factor
4024TF281 49HP
- Prime:
- Power: 43HP (32 kW)
- Calculated Electrical Power: 27 kWe, 34 kVA
- Standby:
- Power: 49HP (36 kW)
- Calculated Electrical Power: 30 kWe, 38 kVA
- Engine Performance Curve
4024HF285 80HP
- Prime:
- Power: 74HP (55 kW)
- Calculated Electrical Power: 45-47kWe, 56-59 kVA
- Standby:
- Power: 80HP (60 kW)
- Calculated Electrical Power: 50-52 kWe, 63-65 kVA
- Engine Spec
- Engine Performance Curve
5030HF285 96HP
- Prime:
- Power: 87HP (65 kW)
- Calculated Electrical Power: 54-56 kWe, 68-70 kVA
- Standby:
- Power: 96HP (72 kW)
- Calculated Electrical Power: 60-63 kWe, 75-79 kVA
- Engine Spec
- Engine Performance Curve
4045TF280 75HP
- Prime:
- Power: 68HP (51 kW)
- Calculated Electrical Power: 43-45kWe, 54-56 kVA
- Standby:
- Power: 75HP (56 kW)
- Calculated Electrical Power: 48-50 kWe, 60-63 kVA
- Engine Spec
- Engine Performance Curve
4045TF280 85HP
- Prime:
- Power: 76HP (57 kW)
- Calculated Electrical Power: 48-51 kWe, 60-64 kVA
- Standby:
- Power: 85HP (63 kW)
- Calculated Electrical Power: 54-56kWe, 68-70kVA
- Engine Spec
- Engine Performance Curve
4045HF280 99HP
- Prime:
- Power: 90HP (67 kW)
- Calculated Electrical Power: 57-60 kWe, 71-75 kVA
- Standby:
- Power: 99HP (74 kW)
- Calculated Electrical Power: 63-66 kWe, 79-83 kVA
- Engine Spec
- Engine Performance Curve
4045HF485 179HP
- Prime:
- Power: 179HP (134 kW)
- Calculated Electrical Power: 112-117 kWe, 140-146 kVA
- Standby:
- Power: 197HP (147 kW)
- Calculated Electrical Power: 140-146 kWe, 124-129kVA
- Engine Spec
- Engine Performance Curve
4045TF285 99HP
- Prime:
- Power: 90HP (67 kW)
- Calculated Electrical Power: 54-57kWe, 68-71 kVA
- Standby:
- Power: 99HP (74 kW)
- Calculated Electrical Power: 61-63 kWe, 76-79 kVA
- Engine Spec
- Engine Performance Curve
4045HF285 126HP
- Prime:
- Power: 115HP (86 kW)
- Calculated Electrical Power: 71-74kWe, 89-93 kVA
- Standby:
- Power: 126HP (94 kW)
- Calculated Electrical Power: 78-82kWe, 98-103kVA
- Engine Spec
- Engine Performance Curve
4045HF285 133HP
- Prime:
- Power: 121HP (90 kW)
- Calculated Electrical Power: 74-78 kWe, 94098 kVA
- Standby:
- Power: 133HP (99 kW)
- Calculated Electrical Power: 83-86 kWe, 104-108 kVA
- Engine Spec
- Engine Performance Curve
4045HF285 158HP
- Prime:
- Power: 144HP (107 kW)
- Calculated Electrical Power: 89-93 kWe, 111-116 kVA
- Standby:
- Power: 158HP (118 kW)
- Calculated Electrical Power: 98-103 kWe, 123-129kVA
- Engine Spec
- Engine Performance Curve
6068HF485 284HP
- Prime:
- Power: 258HP (193 kW)
- Calculated Electrical Power: 164-171 kWe, 205-214 kVA
- Standby:
- Power: 617HP (460 kW)
- Calculated Electrical Power: 400-409 kWe, 500-511 kVA
- Engine Spec
- Engine Performance Curve
6068HF485 315HP
- Prime:
- Power: 286HP (214 kW)
- Calculated Electrical Power: 176-184 kWe, 220-230 kVA
- Standby:
- Power: 315HP (235 kW)
- Calculated Electrical Power: 194-203 kWe, 243-254 kVA
- Engine Spec
- Engine Performance Curve
6068HF285 197HP
- Prime:
- Power: 180HP (134 kW)
- Calculated Electrical Power: 111-116 kWe, 139-145 kVA
- Standby:
- Power: 197HP (147 kW)
- Calculated Electrical Power: 122-128 kWe, 153-160 kVA
- Engine Spec
- Engine Performance Curve
6068HF285 237HP
- Prime:
- Power: 216HP (161 kW)
- Calculated Electrical Power: 133-139kWe, 166-174 kVA
- Standby:
- Power: 237HP (177 kW)
- Calculated Electrical Power: 147-154kWe, 184-193 kVA
- Engine Spec
- Engine Performance Curve
6090HF485 307HP
- Prime:
- Power: 561HP (419 kW)
- Calculated Electrical Power: 364-372 kWe, 455-465 kVA
- Standby:
- Power: 617HP (460 kW)
- Calculated Electrical Power: 400-409 kWe, 500-511 kVA
- Engine Spec
- Engine Performance Curve
6090HF485 346HP
- Prime:
- Power: 315HP (235 kW)
- Calculated Electrical Power: 197-206 kWe, 247-258 kVA
- Standby:
- Power: 346HP (258 kW)
- Calculated Electrical Power: 218-228 kWe, 273-285 kVA
- Engine Spec
- Engine Performance Curve
6090HF485 385HP
- Prime:
- Power: 350HP (261 kW)
- Calculated Electrical Power: 219-229kWe, 274-286 kVA
- Standby:
- Power: 385HP (287 kW)
- Calculated Electrical Power: 243-254 kWe, 304-317 kVA
- Engine Spec
- Engine Performance Curve
6090HF485 422HP
- Prime:
- Power: 384HP (287 kW)
- Calculated Electrical Power: 241-252 kWe, 302-315 kVA
- Standby:
- Power: 422HP (315 kW)
- Calculated Electrical Power: 266-278kWe, 333-348kVA
- Engine Spec
- Engine Performance Curve
6135HF485 463HP
- Prime:
- Power: 416HP (311 kW)
- Calculated Electrical Power: 264-376 kWe, 330-345 kVA
- Standby:
- Power:463HP (345 kW)
- Calculated Electrical Power: 293-306kWe, 367-383 kVA
- Engine Spec
- Engine Performance Curve
6135HF485 538HP
- Prime:
- Power: 489HP (365 kW)
- Calculated Electrical Power: 310-324 kWe, 388-405 kVA
- Standby:
- Power: 538HP (401 kW)
- Calculated Electrical Power: 341-356 kWe, 426-445 kVA
- Engine Spec
- Engine Performance Curve
6135HF485 617HP
- Prime:
- Power: 561HP (419 kW)
- Calculated Electrical Power: 364-372 kWe, 455-465 kVA
- Standby:
- Power: 617HP (460 kW)
- Calculated Electrical Power: 400-409 kWe, 500-511 kVA
- Engine Spec
- Engine Performance Curve
Estimated Dimensions (inches)
| Model | Height (H) x Length (L) x Width (W) |
|---|---|
| 4024T | Call for dimensions |
| 4024H | Call for dimensions |
| 5030H | Call for dimensions |
| 4045T | Call for dimensions |
| 4045H | Call for dimensions |
| 6068H | Call for dimensions |
| 6090H | Call for dimensions |
| 6135H | Call for dimensions |
Standard Equipment:
- John Deere engine
- AC brushless generator w/ 1% regulation
- Unit mounted circuit breaker
- 3 to 5% mechanical generator
- Radiator cooling system with 110° F ambient rating(minimum)
- Vibration isolated, unit mounted control panel with AC voltmeter, AC ammeter, AC frequency meter, selector switch, start/stop control, oil pressure, engine coolant, and elapsed time meter gauges
- Automatic shutdown for high coolant temperature and low lube oil pressure
- Dry type air cleaner
- Industrial silencer
- Complete unit mounted on structural steel base
Optional Equipment:
- Automatic controls
- Transfer switches
- Remote and customized instrument panels
- Trailer mounted
- Enclosures (weather-proof & sound attenuated)
- Heavy duty air cleaners
- Special grade silencers
- Trickle chargers
- Batteries
- Fuel Tanks
- Other options available, please inquire.